Low Temperature Chillers Manufacturer
Ultra Low Temperature Chillers
- The ultra-low temperature chiller adopts single-machine self-cascading refrigeration technology, the lowest temperature can reach -150 ℃, the refrigeration effect is good and the speed is super fast. Fully meet your temperature control needs. The accessories of the equipment can be customized according to your actual requirements.
- Professional low-temperature and ultra-low temperature refrigeration equipment can be tailored for you. At the same time, this device also supports customized explosion-proof series, and the explosion-proof level conforms to national safety standards.
LNEYA Model | Temp. range °C | Cooling capacity kW | Circulating pump m³/h bar | Expansion tank | Power |
LC-12W | -25 ~ -5 | 12kw @ -20°C | 6.6 2.5 | 100L | 380V 50HZ 12kW |
LC-20W | -25 ~ -5 | 20kw @ -20°C | 9 2.5 | 175L | 380V 50HZ 12kW |
LC-30W | -25 ~ -5 | 30kw @ -20°C | 15 2.5 | 250L | 380V 50HZ 28kW |
LC-40W | -25 ~ -5 | 40kw @ -20°C | 15 2.5 | 350L | 380V 50HZ 38kW |
LC-60W | -25 ~ -5 | 60kw @ -20°C | 25 2.5 | 500L | 380V 50HZ 50kW |
LC-80W | -25 ~ -5 | 80kw @ -20°C | 25 2.5 | 600L | 380V 50HZ 61kW |
LC-120W | -25 ~ -5 | 120kw @ -20°C | 25 2.5 | 750L | 380V 50HZ 86kW |
LC-180W | -25 ~ -5 | 180kw @ -20°C | 35 2.5 | 1000L | 380V 50HZ 127kW |
LC-240W | -25 ~ -5 | 240kw @ -20°C | 35 2.5 | 1350L | 380V 50HZ 167kW |
LC-360W | -25 ~ -5 | 360kw @ -20°C | 50 2.5 | 1800L | 380V 50HZ 247kW |
LJ-6W | -45 ~ -10 | 12kw @ -20°C | 6.6 2.5 | 50L | 380V 50HZ 102kW |
LJ-10W | -45 ~ -10 | 20kw @ -20°C | 9 2.5 | 80L | 380V 50HZ 21kW |
LJ-15W | -45 ~ -10 | 30kw @ -20°C | 15 2.5 | 150L | 380V 50HZ 30kW |
LJ-20W | -45 ~ -10 | 40kw @ -20°C | 15 2.5 | 180L | 380V 50HZ 40kW |
LJ-30W | -45 ~ -10 | 60kw @ -20°C | 25 2.5 | 200L | 380V 50HZ 60kW |
LJ-40W | -45 ~ -10 | 80kw @ -20°C | 25 2.5 | 250L | 380V 50HZ 70kW |
LJ-60W | -45 ~ -10 | 120kw @ -20°C | 25 2.5 | 400L | 380V 50HZ 100kW |
LJ-90W | -45 ~ -10 | 180kw @ -20°C | 35 2.5 | 1000L | 380V 50HZ 127kW |
LJ-120W | -45 ~ -10 | 240kw @ -20°C | 35 2.5 | 1350L | 380V 50HZ 167kW |
LJ-180W | -45 ~ -10 | 360kw @ -20°C | 50 2.5 | 1800L | 380V 50HZ 247kW |
LN-6W | -60 ~ -10 | 6kw @ -55°C | 6.6 2.5 | 100L | 380V 50HZ 14kW |
LN-10W | -60 ~ -10 | 10kw @ -55°C | 9 2.5 | 175L | 380V 50HZ 18kW |
LN-20W | -60 ~ -10 | 20kw @ -55°C | 15 2.5 | 350L | 380V 50HZ 35kW |
LN-30W | -60 ~ -10 | 30kw @ -55°C | 25 2.5 | 500L | 380V 50HZ 52kW |
LN-40W | -60 ~ -10 | 40kw @ -55°C | 25 2.5 | 600L | 380V 50HZ 69kW |
LN-60W | -60 ~ -10 | 60kw @ -55°C | 25 2.5 | 750L | 380V 50HZ 104kW |
LN-120W | -60 ~ -10 | 120kw @ -55°C | 35 2.5 | 1350L | 380V 50HZ 200kW |
LN-180W | -60 ~ -10 | 180kw @ -55°C | 50 2.5 | 1800L | 380V 50HZ 300kW |
LNEYA Model | Temp. range °C | Cooling capacity kW | Circulating pump m³/h bar | Expansion tank | Power |
LD-4W | -80 ~ -30 | 4 @ -75°C | 6.6 2.5 | 100L | 380V 50HZ 14kW |
LD-6W | -80 ~ -30 | 6 @ -75°C | 6.6 2.5 | 175L | 380V 50HZ 18kW |
LD-8W | -80 ~ -30 | 8 @ -75°C | 9 2.5 | 250L | 380V 50HZ 30kW |
LD-12W | -80 ~ -30 | 12 @ -75°C | 15 2.5 | 350L | 380V 50HZ 43kW |
LD-20W | -80 ~ -30 | 20 @ -75°C | 25 2.5 | 500L | 380V 50HZ 69kW |
LD-30W | -80 ~ -30 | 30 @ -75°C | 25 2.5 | 600L | 380V 50HZ 101kW |
LD-40W | -80 ~ -30 | 40 @ -75°C | 25 2.5 | 750L | 380V 50HZ 101kW |
LD-60W | -80 ~ -30 | 60 @ -75°C | 35 2.5 | 1000L | 380V 50HZ 200kW |
LD-90W | -80 ~ -30 | 90 @ -75°C | 35 2.5 | 1350L | 380V 50HZ 295kW |
LD-120W | -80 ~ -30 | 120 @ -75°C | 50 2.5 | 1800L | 380V 50HZ 396kW |
LD-180W | -80 ~ -30 | 180 @ -75°C | 65 2.5 | 2200L | 380V 50HZ 588kW |
CDLJ-2W | -110 ~ -50 | 2 @ -105°C | 10 2.5 | 50L | 380V 50HZ 14kW |
CDLJ-3W | -110 ~ -50 | 3 @ -105°C | 14 2.5 | 75L | 380V 50HZ 18kW |
CDLJ-6W | -110 ~ -50 | 6 @ -105°C | 25 2.5 | 150L | 380V 50HZ 43kW |
CDLJ-10W | -110 ~ -50 | 10 @ -105°C | 35 2.5 | 200L | 380V 50HZ 69kW |
CDLJ-15W | -110 ~ -50 | 15 @ -105°C | 45 2.5 | 300L | 380V 50HZ 101kW |
CDLJ-20W | -110 ~ -50 | 20 @ -105°C | 65 2.5 | 300L | 380V 50HZ 101kW |
CDLJ-45W | -110 ~ -50 | 45 @ -105°C | 120 2.5 | 550L | 380V 50HZ 295kW |
CDLJ-60W | -110 ~ -50 | 60 @ -105°C | 180 2.5 | 800L | 380V 50HZ 396kW |
CDLJ-90W | -110 ~ -50 | 120 @ -105°C | 360 2.5 | 1000L | 380V 50HZ 768kW |
SLJ-3W | -150 ~ -110 | 3 @ -120°C | 3m³/h @ 20℃ | / | 380V 50HZ 12kW |
SLJ-4W | -150 ~ -110 | 4 @ -120°C | 4m³/h @ 20℃ | / | 380V 50HZ 16kW |
SLJ-6W | -150 ~ -110 | 6 @ -120°C | 6m³/h @ 20℃ | / | 380V 50HZ 24kW |
SLJ-11W | -150 ~ -110 | 11 @ -120°C | 10m³/h @ 20℃ | / | 380V 50HZ 36kW |
Refrigerated Circulators
- LNEYA specializes in the development and production of low-temperature refrigeration circulators. The refrigeration temperature ranges from-125°C to +30℃. Adopt a computer cascade temperature controller and a PT100 temperature sensor with high temperature control accuracy. The product uses a mixture of ethylene glycol and water for cyclic refrigeration, saving water resources.
- Adopt super-cooling technology to ensure temperature stability at low temperatures; adopt a fully enclosed design to ensure the purity of the cold heat transfer medium, prevent ice crystals, and increase the life of the heat transfer fluid.
- The product adopts the international brand compressor Carlyle, which is small in size and high in efficiency. The single compressor can realize the temperature control of -152 °C, and the ultra-low temperature refrigeration technology is at the international advanced level.
LNEYA Model | Temp. range °C | Cooling capacity kW | Pump Flow Rate, Pressure L/min bar | Expansion tank | Power |
LX-0250N | -25 ~ 30 | 1 @ -10°C | 20 1.5 | 15L | 220V 50HZ 1.5kW |
LX-0400N | -25 ~ 30 | 1.5 @ -10°C | 20 1.5 | 17L | 220V 50HZ 2.2kW |
LX-0700N | -25 ~ 30 | 2.7 @ -10°C | 35 1.5 | 25L | 220V 50HZ 3kW |
LX-1000N | -25 ~ 30 | 6.3 @ -10°C | 35 1.5 | 30L | 380V 50HZ 4kW |
LX-1450N | -25 ~ 30 | 8 @ -10°C | 50 2.5 | 40L | 380V 50HZ 5kW |
LX-2000N | -25 ~ 30 | 12 @ -10°C | 50 2.5 | 60L | 380V 50HZ 6kW |
LX-2600N | -25 ~ 30 | 15.5 @ -10°C | 110 2.5 | 80L | 380V 50HZ 8kW |
LX-3500N | -25 ~ 30 | 21 @ -10°C | 200 2.5 | 150L | 380V 50HZ 12kW |
LX-5000N | -25 ~ 30 | 30 @ -10°C | 250 2.5 | 300L | 380V 50HZ 17kW |
LT-5018N | -37 ~ 30 | 1.5 @ -10°C | 20 0.7 | 15L | 220V 50HZ 1.6kW |
LT-5040N | -45 ~ 30 | 3.2 @ -10°C | 20 0.7 | 20L | 380V 50HZ 2.5kW |
LT-5062N | -45 ~ 30 | 4.5 @ -10°C | 35 1 | 25L | 380V 50HZ 3.5kW |
LT-5090N | -45 ~ 30 | 6.2 @ -10°C | 35 1 | 30L | 380V 50HZ 4.8kW |
LT-50A1N | -45 ~ 30 | 8.3 @ -10°C | 50 1 | 50L | 380V 50HZ 6kW |
LT-50A2N | -45 ~ 30 | 12 @ -10°C | 50 1 | 80L | 380V 50HZ 8kW |
LT-6518N | -60 ~ -20 | 0.7 @ -40°C | 20 0.7 | 15L | 220V 50HZ 3kW |
LT-6530N | -60 ~ -20 | 1.2 @ -40°C | 20 0.7 | 20L | 220V 50HZ 3kW |
LT-6562N | -60 ~ -20 | 2.1 @ -40°C | 35 1 | 30L | 380V 50HZ 4.5kW |
LT-6590N | -60 ~ -20 | 2.8 @ -40°C | 35 1 | 35L | 380V 50HZ 5.8kW |
LT-65A1N | -60 ~ -20 | 4 @ -40°C | 50 1 | 40L | 380V 50HZ 7kW |
LT-65A2N | -60 ~ -20 | 6 @ -40°C | 50 1 | 60L | 380V 50HZ 9kW |
LT-8018N | -75 ~ -20 | 0.4 @ -60°C | 20 0.7 | 15L | 220V 50HZ 3.5kW |
LT-8030N | -80 ~ -20 | 0.8 @ -60°C | 20 0.7 | 20L | 380V 50HZ 4kW |
LT-8062N | -80 ~ -20 | 1.6 @ -60°C | 35 1 | 30L | 380V 50HZ 6kW |
LT-8090N | -80 ~ -20 | 2.1 @ -60°C | 35 1 | 35L | 380V 50HZ 7kW |
LT-80A1N | -80 ~ -20 | 4 @ -60°C | 50 1 | 40L | 380V 50HZ 9.5kW |
LT-80A2WN | -80 ~ -20 | 6 @ -60°C | 50 1 | 60L | 380V 50HZ 11.5kW |
LT-A025WN | -105 ~ -60 | 1.3 @ -75°C | 20 0.7 | 15L | 380V 50HZ 5.5kW |
LT-A050WN | -105 ~ -60 | 3 @ -75°C | 35 1 | 25L | 380V 50HZ 7.5kW |
LT-A080WN | -105 ~ -60 | 5 @ -75°C | 50 1 | 40L | 380V 50HZ 11kW |
LT-A215WN | -115 ~ -70 | 0.7 @ -95°C | 20 0.7 | 15L | 380V 50HZ 6kW |
LT-A230WN | -115 ~ -70 | 1.4 @ -95°C | 35 1 | 25L | 380V 50HZ 9.5kW |
Small Chillers
- The product can be used for cooling the heating part of the semiconductor manufacturing device, cooling the heating part of the laser device, and cooling the heating part of the analysis and detection machine. Some models are specially upgraded, not only for cooling but also for heating, and the temperature control range can reach 5℃ to 35℃, which greatly improves the performance of precision cooling water circulation equipment and expands the application range of the equipment.
- This product can be customized into an explosion-proof series of chillers for use in various hazardous locations. The accessories of the equipment can be customized according to your requirements.
LNEYA Model | Temp. range °C | Liquid storage volume | Heating capacity kW | Cooling capacity kW | Pump Flow Rate, Pressure l/min bar | Power |
FL-800N | -18 ~ 30 | 3.5L | / | 0.9 @ 20°C | 10 0.6 | 220V 50HZ 0.6kW |
FL-0250 | 5 ~ 50 | 15L | 2.5 | 2.5 @ 20°C | 25 2 | 220V 50HZ 1.5kW |
FL-0500 | 5 ~ 50 | 25L | 5 | 5 @ 20°C | 35 2.5 | 220V 50HZ 2.2kW |
FL-0700 | 5 ~ 50 | 40L | 7 | 7 @ 20°C | 35 2.5 | 220V 50HZ 3kW |
FL-1000 | 5 ~ 50 | 40L | 10 | 10 @ 20°C | 50 2.5 | 380V 50HZ 4kW |
FL-1500 | 5 ~ 50 | 60L | 15 | 15 @ 20°C | 75 2.5 | 380V 50HZ 5kW |
FL-2000 | 5 ~ 50 | 70L | 20 | 20 @ 20°C | 75 2.5 | 380V 50HZ 6kW |
FL-2600 | 5 ~ 50 | 100L | 26 | 26 @ 20°C | 110 2.5 | 380V 50HZ 8kW |
FL-3500 | 5 ~ 50 | 200L | 35 | 35 @ 20°C | 200 2.5 | 380V 50HZ 12kW |
FL-5000 | 5 ~ 50 | 300L | 50 | 50 @ 20°C | 250 2.5 | 380V 50HZ 17kW |