Temperature Control Unit for Laboratory Reactor
The temperature control unit for laboratory reactor adopts advanced technology and equipment, combined with modern computer technology and control theory, to achieve real-time monitoring and precise control of the temperature in the reactor. The system can display the temperature changes in the reactor in real time, and display them intuitively through a visual interface, which is convenient for operators to monitor and adjust the reaction process in real time.
Composition of temperature control unit for laboratory reactor
The temperature control unit for laboratory reactor mainly consists of the following parts:
Temperature sensor: used to detect the temperature changes in the reactor in real time, and convert the temperature signal into an electrical signal and transmit it to the control system.
Control system: According to the signal of the temperature sensor, through calculation and control algorithms, the heating or cooling equipment is controlled to adjust the temperature in the reactor.
Visual interface: The temperature data is displayed to the operator in the form of charts, curves, etc., providing an intuitive and clear temperature monitoring interface.
Data recording and processing: The system can record temperature data, analyze and process data, and provide reliable data support for experiments and production.
Features of temperature control unit for laboratory reactor
High-precision control: The system adopts advanced control algorithms and sensor technology to achieve high-precision control of the temperature in the reactor and ensure the stability and accuracy of the temperature.
Visual monitoring: Through the visual interface, operators can intuitively understand the temperature changes in the reactor, which is convenient for real-time monitoring and adjustment of the experiment and production process.
Automatic control: The system can realize automatic control, reduce manual intervention, and improve the efficiency and stability of experiments and production.
Data recording and analysis: The system can record temperature data, analyze and process data, and provide reliable data support for experiments and production.
Application field of temperature control unit for laboratory reactor
The temperature control unit for laboratory reactor is widely used in experiments and production in the fields of chemistry, pharmaceuticals, food, biology, etc., especially in chemical reactions and synthesis processes that require precise temperature control, and plays an important role.
We provide complete temperature control systems design and manufacturing. From standard models to complete customized products. We specialize in customer service and are dedicated to helping each customer have the optimal temperature control system for their specific need.
We provide non-standard customized solutions. Both single cooling chillers and cooling & heating combo units are available.
Email: lilia@lneya.com WeChat ID: +8615251628237 WhatsApp: +86 17851209193
1.Cooling and Heating Systems
Cooling and Heating Systems (SUNDI series)
- Temperature range: -120℃ ~ +350℃
- High-precision, intelligent temperature control
- Cooling capacity: 0.5kW ~ 1200kW
- Fully closed system to extend the service life of thermal fluid
- Each device is load tested for more than 12 hours
Temperature range | -10 ~ +150°C series | -25 ~ +200°C series | -25 ~ +300°C series | -45 ~ +250°C series | -45 ~ +300°C series | -60 ~ +250°C series | -60 ~ +300°C series | -70 ~ +250°C series | -80 ~ +250°C series | -90 ~ +250°C series | -100 ~ +100°C series | ||
Cooling Capacity | 1.5 ~ 15kW | 1 ~ 200kW | 1 ~ 200kW | 0.45 ~ 200kW | 0.9 ~ 25kW | 0.25 ~ 60kW | 0.75 ~ 25kW | 0.4 ~ 15kW | 0.3 ~ 80kW | 0.2 ~ 80kW | 0.45 ~ 80kW | ||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
Cooling and Heating Circulators
- Temperature range: -45℃ ~ +250℃
- Emerson Copeland compressor, reliable quality
- Self-diagnosis function, multiple safety protection devices
- Fully closed system to extend the service life of thermal fluid
- Each device is load tested for more than 12 hours
Temperature range | -25°C ~ +200°C series | -45°C ~ +250°C series | |||||||
Cooling Capacity | 1 ~ 15kW | 0.25 ~ 15kW | |||||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
Cooling and Heating Systems (WTD series)
- (Micro channel / tube reactors specialized)
- Temperature range: -70℃ ~ +300℃
- High-performance circulation pump, more stable temperature control effect
- Wide temperature range to meet the needs of more industries
- Each device is load tested for more than 12 hours
Temperature range | -70°C ~ +300°C | -45°C ~ +250°C | -70°C ~ +200°C | ||||||
Cooling Capacity | 1.1 ~ 7.5kW | 1.5 ~ 5.5kW | 11 ~ 50kW | ||||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
TCU Multi-reactors Temperature Control System
- Temperature range: -120℃ ~ +250℃
- Sealed, repeatable temperature control
- Built-in electric heating thermal oil auxiliary system
- Add cold and heat source heat exchange modules according to needs
- Each device is load tested for more than 12 hours
Temperature range | -45°C ~ +250°C series | -120°C ~ +250°C series | Customized Temperature Control System | RT+10°C ~ +135°C | |||||
Heating Capacity | 25 ~ 80kW | 25 ~ 80kW | Custom | 25 ~ 300kW | |||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
2.Cooling Chillers
Low Temperature/Cryogenic Chillers (Water Cooled)
- Temperature range: -150℃ ~ -5℃
- International brand compressor, high cooling efficiency
- Secondary subcooling technology, fast cooling speed
- Automated control and operation, efficient and energy-saving
- Each device is load tested for more than 12 hours
Six product series
Temperature range | -25°C ~ -5°C | -45°C ~ -10°C | -60°C ~ -10°C | -80°C ~ -30°C | -110°C ~ -50°C | -150°C ~ -110°C | |||
Cooling Capacity | 12kW…360kW | 6kW…180kW | 6kW…180kW | 4kW…180kW | 2kW…120kW | 2.5kW…11kW | |||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
Recirculating Chiller/Refrigerated Circulator (Air Cooled)
- Temperature range: -120℃ ~ +30℃
- International brand compressor, cascade refrigeration technology
- Use ethylene glycol or a mixture of ethylene glycol and water
- Fully sealed design to ensure the purity of the medium
- Each device is load tested for more than 12 hours
Five product series
Temperature range | -25°C ~ +30°C | -45°C ~ +30°C | -60°C ~ -20°C | -80°C ~ -20°C | -120°C ~ -70°C | ||||
Cooling Capacity | 0.8kW…30kW | 0.75kW…12kW | 0.4kW…6kW | 0.2kW…6kW | 0.3kW…5kW | ||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
Small Chillers / Mini Chillers
- Temperature range: -18℃ ~ +35℃
- International brand compressor, stable performance
- Microcomputer controller, adjustment unit 0.1℃
- Energy saving, high temperature control accuracy
- Each device is load tested for more than 12 hours
Two product series
Temperature range | -18°C ~ +30°C | +5°C ~ +35°C | |||||||
Cooling Capacity | 0.35 ~ 0.9kW | 1.8kW…50kW | |||||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
High Temperature Chillers
- Temperature range: -100℃ ~ +80℃
- International brand compressors and other accessories
- Fully sealed design to ensure the purity of the medium
- PLC programmable controller
- Each device is load tested for more than 12 hours
Five product series
Temperature range | +5°C ~ +40°C | -25°C ~ +40°C | -45°C ~ +40°C | -80°C ~ +80°C | -100°C ~ +80°C | ||||
Cooling Capacity | 6kW…40kW | 2kW…15kW | 1kW…8kW | 0.kW…3kW | 1.5kW…3kW | ||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |